Description
Honeywell Y8610U4001 Intermittent Pilot Retrofit Kit
The Y8610U is a complete kit for converting conventional standing pilot systems to intermittent pilot systems. It is used on gas-fired atmospheric furnaces, boilers, and heating appliances. Not for use on direct vent, induced draft, or power burner equipment. Meets ANSI Z21.71 standard for automatic intermittent pilot ignition systems on central furnaces and boilers.
Features
Use with natural or LP gas
Includes gas valve, ignition module, pilot burner hardware, ignition cable, and wiring harness
Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated.
Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed.